﻿BEGIN:VCALENDAR
VERSION:2.0
METHOD:PUBLISH
CALSCALE:GREGORIAN
PRODID:-//WordPress - MECv7.29.0//EN
X-ORIGINAL-URL:https://iibec.org/
X-WR-CALNAME:IIBEC
X-WR-CALDESC:IIBEC is an international association of building envelope consultants. Members specialize in design, investigation, repair, and management of roofing, exterior wall, and waterproofing systems.
X-WR-TIMEZONE:America/New_York
BEGIN:VTIMEZONE
TZID:America/New_York
X-LIC-LOCATION:America/New_York
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20260308T030000
RRULE:FREQ=YEARLY;BYMONTH=03;BYDAY=2SU
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20261101T010000
RRULE:FREQ=YEARLY;BYMONTH=11;BYDAY=1SU
END:STANDARD
END:VTIMEZONE
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-PUBLISHED-TTL:PT1H
X-MS-OLK-FORCEINSPECTOROPEN:TRUE
BEGIN:VEVENT
CLASS:PUBLIC
UID:MEC-dc3adabb7efe88ae26a804e45cc8d245@iibec.org
DTSTART;TZID=America/New_York:20200613T160000
DTEND;TZID=America/New_York:20200613T171500
DTSTAMP:20200609T122256Z
CREATED:20200609
LAST-MODIFIED:20200610
PRIORITY:5
SEQUENCE:0
TRANSP:OPAQUE
SUMMARY:Glass Breakage in Insulated Glazing Units in Spandrel Assemblies
DESCRIPTION:Presented by George P. Torok, CET, BSS Morrison Hershfield Corporation\n\n\n\n\n\n\n\n\n\n\nCurtainwall and window wall systems today commonly use insulating glass units (IGUs) for vision glazing and for spandrel panel cladding. A risk for IGU in insulated spandrels is higher thermal stresses on the glass lites, compared to older approaches with single glazing. When ceramic enamel (frit) opacifiers are used, there is increased stress from solar absorption. Thermal stress is generally addressed by heat-treating at least the opacified lite. Multiple incidences of thermal stress-related fracture of ceramic enameled spandrel glass in North America, Europe, and elsewhere have shown that ceramic enamel weakens glass, reducing the added benefit of heat treatment, so there remains a risk of in-service thermal stress breakage.\nThis presentation will give examples of breakage, describe causes, show results of a test program that shows ceramic enamel reduces the strength of heat-treated glass, and describe options to control the potential for in-service breakage. The discussion will be of interest to building owners, designers, and builders considering the use of curtainwall and window wall systems with opacified glass.\n\n\n\n\n\n\n\n\n\n\n
URL:https://iibec.org/iibec-events/glass-breakage-igu-spandrel/
CATEGORIES:Convention
LOCATION:Virtual Convention
END:VEVENT
END:VCALENDAR
