Introduction ASTM D6083 is entitled “Standard Specification for Liquid Applied Acrylic Coating Used In Roofing.” It was developed in 1995 under the Roofing and Waterproofing Committee, D08. More specifically, it was developed in the NonBituminous Organic Roof Covering Subcommittee. While other authors have written articles describing the test methods in more detail1, this paper endeavors to assist the reader in understanding how the specification came into existence, why it includes the tests listed in the specification, and what the test results really mean from a “real world” perspective. Background First some background about the American Society for Testing and Materials. ASTM is a consensus standards organization. It is composed of individuals who wish to further the understanding and development of methodology, specifications, and standards for a particular technical issue or discipline. In the case of the ASTM D08 Committee (Roofing, Waterproofing and Bituminous Materials), it is comprised of raw material manufacturers, roofing material manufacturers, contractors, specifiers, consultants, architects, testing organizations, code officials, insurance companies, and other interested parties. Herein lies the strength of this organization. The broad diversity of perspectives from these individuals representing all points in the value chain creates a comprehensive oversight on the entire committee’s activities. From a roofing perspective, all facets of the industry are fully represented. The NonBituminous Organic Roof Covering Subcommittee, as the name implies, is composed of representatives who are primarily interested in synthetic roofing materials versus those composed of natural products such as asphalt and coal tar. As a consensus organization, the ASTM committee allows for the viewpoint of the minority in all phases of the balloting process. This ensures that the voice of the dissenting voter is clearly heard and understood during the entire standards process. Purpose of ASTM D6083 ASTM D6083 was developed as a specification for acrylic roof coatings employing previously developed standard test methods found in roofing and coatings disciplines. Its underlying purpose was borne from concerns among the various stakeholders in the roofing industry to establish a minimum level of qualiBY WILLIAM A. KIRN, RRC ty for acrylic roof coatings. It had become increasingly difficult for architects, consultants, specifiers, and contractors to distinguish among acrylic roof coating products. Product data sheets would list values based on a range of different test methods or methods run under different conditions. The reported values could not be compared from one product’s data sheet to another. Moreover, coating manufacturers were unable to educate their customers in differentiating the value of their product versus that of another product. Thus, manufacturers were destined to sell in a pricequality arena only, without any ability to communicate the superior technical performance of their product versus that of a competitor. Ultimately, the purchaser (user or installer) of these roof coatings lacked the necessary information to determine the true value of a particular coating and could not make an educated buying decision. The Tests, What They Mean, and How the Values Were Established Each ASTM test method and the minimum value required to meet the ASTM D6083 standard has been derived after lengthy discussions between all interested parties at the task group level. We shall consider each test independently. The first requirement in the specification is not a numeric performance requirement but is described in the scope of the document. This specification pertains only to waterborne 100% acrylic roof coatings. Thus, it is intended to define the laboratory properties of a successfully performing roof coating, where the coating uses an “allacrylic polymer” as the binder. The specification does not apply to styrenated, urethane, silicone, butyl, or vinyl acetate (or other) polymers used for roof coatings. Viscosity, Weight, and Volume Solids The product viscosity is specified merely as a method for providing information for the user regarding the relative thickness of the coating in the can. Typically, coatings having viscosities on the higher end of the range are more ideally suited for applications on vertical surfaces such as parapets and penetration flashings. Viscosities in the lower range are better suited for rolling or brushing into irregular surfaces or applying over reinforcing scrims where it is desirable for the coating to penetrate and “wick into” the scrim. The weight and volume solids specifications provide some very valuable information about the coating. All coatings are January 2001 Interface • 15 ing from a typical architectural house paint. It is well known that roofs are dynamic and expand and contract due to thermal and loadinduced movement factors. Thus, a fullyadhered coating must be able to tolerate the movement of the roofing membrane substrate to which it is applied, or it will crack and disbond. The test method employed here is ASTM D2370, which was specifically developed for measuring this property in coatings. Figures 1 and 2 show a test specimen in the tester before and after it is elongated. Another method, ASTM D412, has sometimes been cited. However, it is actually intended to measure prefabricated rubber membranes. The mechanical property test measures two parameters—elongation and tensile strength. Elongation is simply how far a material can be stretched until it breaks. Tensile strength is how much force per unit area is required to pull the sample apart. Ideally, a roof coating must have both elongation and tensile strength to be serviceable. If it merely has high elonFigure 2 Figure 1 typically sold on a volume basis. A onegallon can of paint costs $X. However, there is no accounting for the amount of solvent (water being the solvent for a latex coating). Thus, the user has no way of really knowing how much of the coating in the can is actually “usable stuff” and how much is merely solvent. Two coatings may vary widely in cost, simply because one has more water in it than the other. ASTM D6083 has minimum values for both weight and volume solids. While weight solids are easier to measure, volume solids are the best measure of the useable material in the coating. From a simple calculation, if a product has 50% volume solids, a 20 milthick wet film will yield a 10mil dry film. The minimum value which meets ASTM D6083 is 60% weight solids and 50% volume solids. Mechanical Properties The mechanical property specification, Elongation and Tensile Strength, is one of the most important in this standard. The ability of a coating to tolerate movement or dimensional instability is what clearly distinguishes an elastomeric roof coatgation but no tensile strength, the membrane behaves like chewing gum and deforms too easily without recovering to its original shape. If it has high tensile strength but poor elongation, it is brittle and glasslike and will crack when applied to a dynamic roof. The minimum values here are 100% elongation and 200 psi tensile strength. These values were adopted with the help of numerous roof coating manufacturers and contractors who provided empirical data on the performance of acrylic roof coatings applied over a wide range of substrates, roof designs, and climatic conditions. These data were compiled, and the laboratory mechanical property profiles were used as proxy for actual, inservice, successful performance. Simply restated, successfully performing roof coatings were identified from field experience, and their laboratory mechanical properties were measured to identify a minimum performance standard. Products that did not demonstrate successful field performance were also identified, and their mechanical properties were used to identify the specific value or profile which would not meet the laboratory standard. 16 • Interface January 2001 roofmanager ad 1 12/8/00, 20: 1 PM The second part of this requirement involves the use of an accelerated weathering device, commonly called a WeatherOmeter. The actual free films of the roof coating are first exposed in this weathering apparatus for 1,000 hours, then the mechanical properties are reevaluated. This artificial aging simulates extended exposure to sunlight and rain. During this time, it is possible for the coating to change its surface appearance, physical behavior, and mechanical properties. Retesting the mechanical properties identifies any changes in the material that may affect the longterm performance of the roof coating Figure 3 caused by polymer degradation or crosslinking. The surface of the weathered coating is also inspected to determine any change in appearance such as cracking, checking, or erosion. Its appearance after exposure in the WeatherOmeter is recorded. Adhesion Adhesion is also one of the most important criteria of this specification. Figure 3 shows some of the many roofing membrane substrates that can be used for adhesion testing. If the coating does not adhere, it cannot provide protection for the underlying roofing substrate. The ASTM D6083 specification employs either the ASTM C794 or D903 method for measuring peel adhesion. This test uses a cloth strip imbedded into the coating applied to a small piece of the roofing substrate. The test sample is allowed to dry for two weeks at room temperature and tested using an Instron January 2001 Interface • 17 or similar device to determine the force required to peel the coating away at a 180˚ direction. Figure 4 shows a typical test specimen in the tester. The values are reported as pounds per linear inch (pli). A second portion of this adhesion test is to immerse the sample in water after the twoweek drying period. After one week under water, the sample is immediately retested in the same fashion to determine “wet adhesion.” The substrate used for the adhesion test must be specified. Since there are numerous roofing substrates (and not all coatings are recommended for all substrates), the specification allows the producer to stipulate the substrate that was tested. The minimum values are 4.0 pli for dry adhesion and 2.0 pli for wet adhesion. In the same fashion as the mechanical property minimum values, these laboratory adhesion values were obtained based on successfully performing roofs over the specified substrate. Primers may be used in this test, but they must be acknowledged in the documentation. Figure 5 shows one sprayed poly ure thane foam (SPF) panel demonstrating adhesive failure where the coating peels away cleanly while the other shows cohesive failure where the coating adheres preferentially to the SPF roof substrate rather than the cloth strip. In this case, the true adhesion value is actually greater than the recorded value from the test equipment. Low Temperature Flexibility After Accelerated Weathering It is imperative that any roof coating has sufficient tolerance for movement and dimensional change of the roofing substrate at low service temperature. Most thermoplastic materials, such as coatings, have lower elongation or flexibility at low temperatures than they do at room temperature. Therefore, it is vital that the coating be tested for low temperature flexibility. In this case, ASTM D522 is employed. This test actually joins two tests to yield increased value from the testing protocol. Metal panels (with the roof coatings applied) that were exposed to the accelerated weathering apparatus to measure surface appearance are then chilled in a freezer. Next, the low temperature flexibility profile is measured by bending the coated metal panel over mandrels of decreasing diameter. If the coating becomes brittle on weathering, the film will not pass the low temperature flexibility test. The requirement here is for the coating to pass a 1/2inch mandrel bend at 15 ˚ F. While this temperature may seem too stringent to be considered as simulating some environments, such as Miami, Florida, or Phoenix, Arizona, the task group that drafted the specification felt that it would be possible for a product to perform successfully in some geographies, only to fail in colder climates. Thus, a single specification was established for low temperature flexibility. Figur e 4 Figure 5 January 2001 Interface • 21 Figure 6 Figure 7 Tear Resistance Tear resistance is a method for determining the ease with which a film of the roof coating can be torn using an Instron tester. This test is based on ASTM D624. The test simulates the propagation of a tear in a roof coating that has delaminated from the roofing substrate. Once again, minimum values were established based on the field performance of over 20 actual roofs in service throughout the US, ranging in age from 3 to 20 years over bitumen, single ply, metal, and sprayed polyurethane foam substrates. Permeance and Water Swelling The water resistance of the coating is measured by two ASTM methods. The first is D1653, a measure of the permeance of the coating. Figure 6 shows the typical cup that is used for this test. Since these acrylic coatings are waterborne, they are inherently “breathers.” That is, they have water vapor permeance greater than 1.0. Ironically, if the coating had an extremely low permeance (less than 0.5) it would be a vapor retarder and probably never fully dry because water (the solvent for the latex roof coating) would be trapped in the coating film during the drying process. These coatings function similarly to GoreTex® fabric used for camping and outdoor clothing. Once dry, they have the ability to prevent the passage of bulk water, while still allowing moisture vapor to move through the dry film coating matrix. The specification calls for a maximum of 50 perms for a 20mil thick film. In actual field practice, the permeance of the coating usually drops to less than 10, as the water soluble components of the coating leach out after water contact from dew or rain. Thus, the actual inservice permeance value is considerably lower than the specification. 22 • Interface January 2001 Figure 8 Water swelling is the second component test for water resistance. This is measured by D471. A typical setup is shown in Figure 7. The purpose of this test is to determine how “spongelike” the coating film is. Since it is possible for these coatings to imbibe water, thus reducing their inherent performance properties, this is an important value when judging a coating’s laboratory performance. Simply described, a coating film is placed in a beaker of water and removed periodically and weighed while wet. The percent weight gain is recorded. A plot of water swelling is shown in Figure 8. The minimum values for this test and the permeance test were derived from evaluating actual roof coatings that were performing satisfactorily in ponded water areas and establishing maximum values based on these tests. The swelling test shown in Figure 9 is important, since, as the coating swells, it creates stresses at the coating/roof substrate interface. The greater the swelling, the greater the stress and the greater the propensity for the coating to delaminate from the roof. It should be noted that while the roofing community often asks about the ability of a coating to withstand ponded water, the real concern (and the one most consistent with the demands of water immersion) is the wet adhesion test. The ponding water question is really best restated as, “How good is the wet adhesion?” Fungi Resistance The final test is fungi resistance as measured by ASTM G21. Fungi are biological microorganisms that grow on moist surfaces. To maintain appearance, a successfully performing roof coating must have some measure of fungi resistance built into the formulation. Again using field performance as a guide, the minimum level of fungi resistance was established. Since the fungi resistance of a roof coating is derived from the fungicidal additives that are incorporated into the coating, it is expected that the resistance slowly lessens with actual service. This is particularly true on roofs that have poor drainage with continuous standing water, as these additives more quickly leach out and biological growth conditions are optimal. Figure 9 Conclusions ASTM D6083 is the product of literally hundreds of hours of concerted efforts by participants to establish a minimum laboratory standard that can serve as a general proxy for actual field performance. Selection of tests and minimum standards was based on the actual, successful, inservice performance of acrylic roof coatings sold by numerous manufacturers on over 20 roofs ranging in age from a few to 20 years old, located throughout the US and applied on various roofing substrates. Thus, anyone using this standard in specifying or installing an acrylic roof coating will have additional confidence that that particular coating should perform successfully when properly applied. ■ Reference 1. Seyfried, E. “RCMA in Review: ASTM D6083 Made Easy,” RSI, March 2000. Bill Kirn has been employed by Rohm and Haas Company since 1973 and is currently a Market Manager for Roof Coatings in the North American Coating Business Team. Prior to moving into marketing, he spent 22 years in research, developing improved acrylic products for a wide range of construction applications. He holds four U.S. patents for a wide range of chemical applications. Bill is an RRC and on the faculty of RIEI. He is Secretary of the Polymeric Materials Subcommittee of ASTM D08 (Roofing and Waterproofing) and a member of E06 (Building Performance). Kirn currently chairs the Technical Committee of the Cool Roof Rating Council and is a mem ber of CSI and the Roof Coating Manufacturers Association. He holds a bachelor’s degree in Chemistry from Temple University, a masters in Organic Chemistry from St. Joseph’s University, and an MBA from Temple University. ABOUT THE AUTHOR BILL KIRN January 2001 Interface • 23