Why We Need to Rethink the Business of Mid-Rise Wood Frame Student Housing

Back To News
October 1, 2019
By Derek Hodgin, RBEC, RRO, PE, CDT

Why We Need to Rethink the Business of Mid-Rise Wood Frame Student HousingWhile mid-rise wood frame construction has its own set of unique challenges,1 the student housing version of this relatively new product represents the “perfect storm” where the risk of performance issues is drastically increased.2 This opinion is based on the extent of problems that the author has investigated over the past few years, as well as personal knowledge and observation of multiple student housing projects during construction. The frequency of student housing cases (e.g., structural failure, water damage, etc.) seems to be increasing, as more of these buildings spend time in service and begin to show signs of distress. The author felt strongly enough about this issue to send the letter in Figure 1 to two prominent national newspapers in early 2018:

Many college students are currently living in recently constructed mid-rise wood frame buildings that are intended to meet minimum building code requirements to be reasonably safe and durable. The mid-rise wood frame student housing business is huge. There has been such a tremendous amount of construction that competition to sell beds is fierce. The industry has responded by spending money on amenities and marketing gimmicks to attract students, rather than on improved construction quality. Our forensic engineering firm has investigated water intrusion, wood rot, termites, fire safety issues, and structural failures on more than 20 mid-rise wood frame projects in the last two years, and they are becoming more frequent.

Combining code-minimum construction with disconnected student occupants (who may occasionally be less than mature) is a terrible idea that has (and will continue) to result in problems. There is a reason that traditional university dorms were constructed to be institutional-grade buildings. To sit back and continue to defend our current path by saying that it is allowed by the building code is irresponsible and shows a lack of understanding. As a Professional Engineer, I am required to protect the welfare and safety of the public. Until the building code changes, or we figure out alternate ways to improve construction practices, we will continue to deal with predictable problems of safety and durability. Unfortunately, any significant changes in the building code are historically preceded by a tragedy. With as much evidence as we already have regarding performance issues, you would think that we could be proactive and make changes now, instead of waiting for the tragedy.

Students deserve safe and durable buildings; we are currently not doing a good job delivering. Just because something is allowed, or provides an attractive return on investment, does not make it a good idea. We have an opportunity to put the brakes on minimum code-compliant mid-rise wood frame student housing and implement requirements to improve construction practices. There are fellow engineers and architects, manufacturers of building components, and students and professors across the country who would likely be available to collaborate on revising existing standards and developing incentives for constructing better buildings. Others (elected officials, firefighters, building officials, and construction experts) are speaking out across the country to make changes to this segment of construction; now is the time to join the discussion, not after we allow more potential problems to be constructed!

We keep saying: “If you see something, say something.” I am saying something.

Derek Hodgin, PE
Clemson, SC

Figure 1 – Letter to the editor sent March 18, 2018

I received a response from the newspapers that: 1) the topic was not relevant, and 2) I was not responding to anything.

Our firm has recently consulted on two collapses of wood frame floors and a collapse of a wood frame deck in student-occupied buildings. College students have much greater potential of generating dynamic loading conditions on floor framing due to dancing and deciding to “see what happens if we all jump together!” as reported in one of our floor collapse cases (Figure 2).

damaged wood
Figure 2 – View of damaged wood truss due to dynamic condition.
After our most recent wood frame floor collapse case made national news in October of 2018, the letter above was sent again to both newspapers. They were asked to reconsider if the letter was relevant, and they were informed that the letter was responding to the floor collapse that was currently in the news. A response was never received from either newspaper, and the letter was never printed.
collapsed floor
Figure 3 – View of collapsed floor framing.

The Problems

There are many factors that make the combination of mid-rise wood frame construction and student housing a predictable problem. Some of the factors are construction related and some are not, but all can have an effect on the final product. The most significant factors are described below.

Inflated Real Estate Prices

Most student housing projects are located proximate (within walking distance if possible) to a college campus, in an urban environment, where land prices are at a premium. This is particularly true after the first mega-sized student housing project breaks ground. Adjacent landowners cash in on the student housing potential by selling any and all property near campus at inflated prices. The inflated real estate prices directly contribute to the poor construction practices by forcing the developer to: 1) maximize the scale of the project, 2) value-engineer all of the best-practice details out of the project, 3) build to code-minimum standards, and 4) select low-bid contractors.

Unreasonable Contracts/Rushed Schedules

Because the economics of student housing are based on selling beds, most projects are required to be completed in August, at the start of the fall semester, regardless of when the project was started. When a hard finish date is desired, contracts can become unreasonable in terms of penalties and bonuses for late or early completion, respectively. The frenzy to complete projects in time to rent beds has resulted in haphazard sequencing that has caused significant damage during construction.

A recent student housing project was damaged by water intrusion that was directed into the unprotected wood framing of the building due to improper sequencing of the roofing membrane and associated drains. This project required significant repairs before it was even completed.

Another project trapped water in the exterior wall assembly due to rain events that occurred while the walls were in a variety of stages of completeness. Areas of incomplete weather-resistant barrier (WRB) served to trap and funnel water into the wall assembly, where it remained while the wall construction continued, with no efforts to dry out the wall (Figure 4).

overlapping steps
Figure 4 – View of a building in various stages of construction.

Misguided Budgets/Delivery Methods

With so much student housing being constructed, the competition for selling beds is stiff. Since students care most about convenience and amenities, and less about quality construction, construction budgets get trimmed in all of the wrong places. Specifically, in all of these markets there appears to be an all-out amenity war. It is no longer acceptable to only have a pool, lazy river, and fitness center. To attract more students, most current projects include volleyball, a DJ booth, hip communal spaces, frequent social functions, and an array of promotional giveaway gear fashioned in school colors (Figure 5).

swanky digs
Figure 5 – View of the interior of student housing building.
The money spent on amenities and marketing makes it difficult to maintain adequate budgets for anything above and beyond code-minimum construction. Most of the student housing projects investigated to date have been constructed to minimum standards and lack durability, as evidenced by construction litigation and/or repairs that commenced within only a few years after completion.

Value Engineering

“Value engineering” is the term used to describe an alternate product and/or detail that is associated with a savings in time and/or money that does not compromise the performance of the delivered product. It is unclear why the term “engineering” became associated with this process, since engineers are rarely included. In most cases, this process is undertaken by the contractor and owner.

In the context of construction litigation, the author has observed that in nearly all cases in which value engineering was undertaken, the performance of the delivered product was compromised. While we have the technology and the products available to construct reasonably durable buildings, the specific product of mid-rise wood frame student housing is not conducive to implementing these “best-practices” due to schedule and budget constraints. In most cases, construction litigation is associated with these buildings being constructed to code-minimum standards, which (for this type of building) has repeatedly been found to be inadequate to provide reasonable durability as intended by the building code.

A recent example of a value engineering failure involved balcony waterproofing details. While the project plans depicted a well-known waterproofing system, a decision was made to replace the best-practices waterproofing system with a code-compliant waterproof coating over a flat wood balcony subfloor and cover the waterproofing with a concrete topping slab. Significant water intrusion and rot were documented within five years after the project was completed. The balcony repairs that are now required will be significant. Fortunately, no one was injured or physically harmed by the resulting damages (Figure 6).

water-damaged balcony
Figure 6 – View of water damage at balcony.

Disconnected Occupants/Improper Repairs

In owner-occupied buildings, problems are typically dealt with as they present themselves. In apartment buildings, problems are dealt with when the issue becomes serious enough for the tenant to complain about it. In student housing projects, the occupants are more disconnected and are less likely to complain about issues until they disrupt their quality of life.

In order to keep the buildings occupied, significant repairs are rarely performed. The author has observed multiple “repairs” that were simply performed to mask a problem, such as towels stuffed along windowsills to soak up water and repeated applications of paint and caulk. To perform a proper repair would involve evaluating the cause of visible distress, potentially including destructive testing. This process would possibly interrupt the occupancy of a unit and impact rental revenue. Therefore, “band-aid” repairs are commonly implemented to temporarily deal with problems and satisfy the tenant. Meanwhile, the cause of the problem is not dealt with, and the damages grow over time.

The Solutions

Liability Issues

In the author’s opinion, the IIBEC membership is the most qualified group of individuals to improve the durability and safety of mid-rise wood frame student housing projects. However, given the litigious nature of the construction industry, it is somewhat intimidating to offer assistance on these types of projects, regardless of one’s level of expertise and experience. While we may be offering solutions to temporarily improve building enclosure and/or structural performance, there remains a disadvantage to repairing large buildings that are framed with moisture-sensitive wood framing, tend to move more than most buildings, and are subject to potential abuse and/or misuse by high-impact occupants.

In the author’s opinion, this is a real issue that will need to be addressed by IIBEC to protect its consultant membership against undue liability. Specifically, qualified IIBEC members should be able to offer assistance with original design and/or repairs to student housing projects without significant concern for exposure to litigation related to non-performance issues. Numerous construction litigation projects have included qualified waterproofing consultants as defendants. In most cases, the consultant provided objective and thoughtful input to the project during construction. Many issues identified by the consultant (e.g., flashing details, flood testing, mock-ups, etc.) were not addressed by the contractor, and the consultant was sued by the overzealous plaintiff attorney without merit. Unless more robust agreements can be used, qualified and experienced consultants will remain in the crosshairs of construction litigation attorneys—particularly if there is viable insurance money available to collect. This could be the subject of an entirely different article.

Occupancy Type

Should there be a student occupancy type added to the building code? In the author’s opinion, this should absolutely be considered. Many structural failures associated with wood-frame student housing projects are associated with the behavior of the occupant. If we allow college students to occupy these buildings, shouldn’t we anticipate college student behavior? This behavior could include dynamic loading conditions, as well as live load conditions above and beyond those anticipated by typical residential occupancies.

Construction Type

Should student housing greater than three stories be required to be Type 1 or 2 construction? This would be a simple solution to provide more robust buildings for this type of occupancy. As stated by the letter at the top of this article, there is a reason that college dormitories have traditionally been constructed to be commercial-grade structures that last for decades.

With minor exception, college-funded projects are still constructed in a more durable, long-lasting manner. However, the author is currently investigating problems with a wood frame dormitory project at a major university that has been taken out of service after only two years. In this case, the university was talked into value engineering the dormitory by switching the construction to wood framing—a decision that has resulted in significant problems, costly repairs, and displaced students.

Best Practices

As an industry, we need to figure out how to provide incentives for contractors to deliver buildings that incorporate best practices. These types of projects will continue to have significant problems (and costly repairs) if we continue constructing to code-minimum standards.

The 2018 International Building Code (IBC)3 took a positive step by requiring the waterproofed surface of balconies to be sloped. While this may seem like a fundamental requirement, it was not previously addressed by the IBC, and thousands of wood frame balconies were constructed with waterproofing installed over flat (or reverse-sloped) wood framing. These conditions caused significant damages in a short period of time. This is only one example of a condition that has been allowed by the building code, but can result in damage and/or failure. Other examples of problematic conditions allowed by the code (that we should consider changing) include those in Table 1.

Code -Allowed ConditionPotential Consequence
Providing code-minimum slope on wood frame roofsDeflection, ponding, roof leak, collapse 4,5
Not providing good drainage details on balconies and walkwaysWater intrusion, rot, deflection, collapse
Installing canopy anchors in brick veneer after the brick is installedCompromised drainage plane, water intrusion, rot
Over-driving nails in coated OSB wall sheathingWater intrusion, rot, corroded fasteners
Installing brick veneer against the bottom of a window 6Brick damage, window damage, water intrusion, rot
Not allowing for vertical and lateral building movements 7,8Broken plumbing fixtures, cladding component damage, water intrusion, rot
Constructing exterior walls with poor drainage characteristicsWater intrusion, rot
Not providing a vertical offset at balcony doorsWater intrusion, damage to interior flooring, rot
Not requiring a building envelope inspectionPoor construction details, building damage, construction litigation
Allowing paint to be used to provide fire resistance in wood construction 9Unknown fire resistance due to water damage, nail penetration, cut edges, abrasion, and absence of repairs
Table 1

Conclusions/Call to Action

If we continue to allow student housing projects to be constructed using typical mid-rise wood frame details, we can expect to continue investigating problems associated with numerous issues, including those identified by this article. If we do not change our course regarding this type of construction, we will increase our chances of an eventual tragedy.

Collaboration is needed to make a change in this part of our industry. The author is currently working on putting together a group of college town municipalities in South Carolina that are affected by these issues and will propose code changes to the South Carolina Building Code Council for these types of projects. Please consider stepping up to do your part to make a change.

References

  1. Derek A. Hodgin. “Mid-Rise Wood Frame Construction: A Good Idea or Are We Asking for Trouble?” Interface. IIBEC. September 2017: pp. 23-33.
  2. Lonnie Haughton. “Berkeley Balcony Collapse.” Interface. IIBEC. February 2019: pp. 29-34.
  3. International Building Code (IBC).“2304.12.2.5.” International Code Council, Washington, DC. 2018.
  4. Scott D. Coffman. “1/4 in 12 Design Slope and Water Drainage: Part 1.” Wood Design Focus. Winter 2017:pp. 1-16.
  5. Scott D. Coffman. “Low-Slope Roof and Deck Design Considerations to Mitigate Ponding and Water Intrusion: Part 2.” Wood Design Focus. Winter 2017: pp. 17-22.
  6. R. Terry Malone. “Options for Brick Veneer on Mid-Rise Wood-Frame Buildings.” WoodWorks. October2015: pp. 1-8.
  7. Stephen A. Mayhew and BrianJ.Pashina. “Avoiding Common Oversights in Design and Construction of Mid-Rise Wood-Framed Buildings.” Proceedings ofthe 31st RCI International Conventionand Trade Show. IIBEC. March2016: pp. 69-79.
  8. Richard McLain and Doug Steimle. “Accommodating Shrinkage in Multi-Story Wood-Frame Structures.” WoodWorks. 2017: pp. 1-17.
  9. Uniform Evaluation Service (UES). “Evaluation Subject: Wood Structural Panels with Flamex™ Factory Applied Coating.” Number 173.2016.
hodgin headshotDerek A. Hodgin, of Construction Science and Engineering in Westminster, SC, has over 25 years of experience as an engineering consultant and is responsible for facility condition inspections, failureanalysis, damage assessments, and forensic engineering investigations of all types of structures. A large part of his projects included analysis of deficient construction cases, including roofs, exterior walls, windows, doors, structural framing, civil site work, and building code review.

One response to “Why We Need to Rethink the Business of Mid-Rise Wood Frame Student Housing”

  1. Derek:

    I have witness multiple issues of similar nature and totally agree with your observations and conclusions. It is time that this type of construction be corrected with the design community as well as with the Owner/Developers forcing the less is more mentality in stick construction with OSB and building wraps. Unfortunately, there are so many buildings in this category (and multi-family housing) that are going to fail in the years to come. Costs will be incurred by those building Owners that have acquired buildings insufficient in design and construction to withstand normal seasonal climatic changes as well as occupant induced trauma. We need to encourage better design with better materials and walk away from anything not proven reliable.