Testing Standards for Slate Roofing

May 15, 2008

Over the last two decades,
new standards have been
developed to address quality
issues for slate roofing.
Testing procedures and
techniques vary widely, and
results show this. It was assumed by many
that slates from the same region or company
were identical in quality, but this is not
correct. Different continents and countries
set up their own standards, which makes it
difficult to compare slate from different
parts of the world. In the U.S., the American
Society for Testing and Materials (ASTM)
oversees the grading of roofing slate. Now
more than ever, roofing slate from different
quarries, regions, and countries needs to be
com pared with regard to durability and
quality.
Originally, three tests were developed to
grade slate under one standard, ASTM C
406. These tests, developed in the 1930s,
were used to categorize U.S.-produced roofing
slate. The test series consisted of ASTM
C 217, Depth of Softening; ASTM C 121,
Water Absorption; and ASTM C 120,
Modulus of Rupture.
ASTM C 217, Depth of Softening
This test is based on the fact that slate,
which contains pyrite, calcite, and carbon,
undergoes a chemical weathering that re –
sults in the conversion of the calcite particles
to gypsum. The resulting swelling causes
disintegration of the slate. The extent of
this action on various slates in the test has
been found to correlate with the durability
of the materials in actual weathering.
ASTM C 121, Water Absorption
The water absorption test attempts to
quantify the percentage of water a slate
absorbs after being immersed for 48 hours.
The correlation has been made that the
greater the absorption percentage, the more
susceptible the slate is to freeze/thaw
cycles, which would directly reduce the
expected service life of the slate.
The above-mentioned tests attempt to
calculate the detrimental effects of erosion
on materials. Like the more predictable
tests associated with ASTM, they have
remained relatively unchanged since their
inception. They are often regarded as the
two most dependable methods of determining
a slate’s potential longevity. The third
component of the ASTM C 406 series has
proven to be somewhat less predictable.
ASTM C 120, Modulus of Rupture
The modulus-of-rupture test attempts
to simulate the effects of foot traffic and hail
on natural roofing slate. The test tries to
quantify the amount of load that can be
placed upon a slate before it fails. The
assumption is made that more impervious
materials can withstand more force. Their
increased durability would presumably
result in increased longevity upon installation.
Unlike the absorption and depth-ofsoftening
test, the modulus-of-rupture test
focuses on the manufacturing practices
used by quarries to produce roofing slate.
The absorption and softening levels associated
with a slate are intrinsic mineral properties
that cannot be manipulated by a
38 • I N T E R FA C E OC T O B E R 2008
manufacturing technique. However, a quarry
can modify the thickness of a slate, and
the results of the modification can have
great bearing on the reported durability of
the slate.
ASTM arbitrarily introduced the standard
level of 9,000 psi for 3/16-inch, commercial,
standard-thickness slate. This
number was determined after experiments
indicated all slate of U.S. origin would meet
or exceed this level. The standard was not to
be applied to slates of greater thickness.
There was no scientific basis that the 9,000-
psi level would indeed lead to a serviceable
life of 75+ years. The level was derived purely
by an assumption, and the actual
requirement is probably low. ASTM changed
this part of the standard, now C 120-05, in
2006. The level now used is load, calculated
in pounds, with a minimum of 575 lb for S-
1 slate, the highest grade.1
These standards were used to replicate
the most common causes of failure.
Consequently:
• The water absorption limit for S-1
slate is 0.25% (ASTM C 121-90).
• The water resistance (depth of softening)
for S-1 slate is 0.002 in
(ASTM C 217-94).
• The modulus of rupture for S-1 slate
is 575 lb (ASTM C 120-05).
Tables 1 to 3 review the results of a
Vermont slate tested in 2007.
Table 1 – Water absorption test results on
Vermont slate tested in 2007.
WATER ABSORPTION
Specimen No. Absorption %
1 0.164
2 0.199
3 0.221
4 0.186
5 0.205
6 0.160
Average 0.189%
Amber Consulting Company
Semi-Weathering Gray/Green
South Poultney/Wells Quarry
Table 2 – Modulus-of-rupture test data on Vermont slate in 2007.
MODULUS OF RUPTURE
Specimen # Load (lb) Thickness (in) Stress (psi)
1 568 0.251 6,796
2 787 0.246 10,253
3 886 0.267 9,384
4 935 0.270 9,677
5 900 0.323 6,515
6 953 0.321 6,977
7 970 0.341 6,291
8 638 0.283 6,021
9 945 0298 8,031
10 1,335 0.315 10,154
Average 892 0.291
Amber Consulting Company
Semi-Weathering Gray/Green; South Poultney/Wells Quarry
Table 3 – Weather resistance test data on
Vermont slate in 2007.
WEATHER RESISTANCE
Specimen # Depth of Softening (in)
1 0.0011
2 0.0013
3 0.0020
Average 0.0015
Amber Consulting Company
Semiweathering Gray/Green
South Poultney/Wells Quarry
Table 4 – Test results for material quality and static uplift.
PROPERTY ASTM TEST METHOD RESULT ASTM C 406 REQUIREMENT
Modulus of rupture across the grain; min; (psi) C 120 9,379 9,000
Absorption: max (%) C 121 0.23 S1 S2 S3
0.25 0.36 0.45
Depth of softening: max (in) C 217 0.002 S1 S2 S3
0.002 0.008 0.014
Broken corners (exposed area): (in) C 406 ½ ≤1½
Curvature max: (in) C 406 1/16 1/8
Knots or knurls on nonexposed surface: (in) C 406 None ≤1/16
Ribbons: inspection (pass/fail) C 406 Pass None
Face dimension variation from specified: C 406 Pass ± 1/8
inspection (pass/fail)
OC T O B E R 2008 I N T E R FA C E • 3 9
Modulus-of-rupture tests are conducted
on a Tinius Olsen testing machine. The
weather-resistance tests are conducted
using the hand scraping method. Thickness
measurements were taken at different locations
along the scrape tract. The average
depth of softening was recorded.
This provides the information that the
manufacturer, specifier, architect, contractor,
and purchaser need to understand the
material quality issue. The slate tested,
which meets S-1 standards, will provide
serviceability of 75+ years. Current testing
results should be available from all manufacturers
on their specific products for distinct
quarry locations. If not, the quality of
the material should be in question, as S-1
slate should be the only material used for a
quality, long-lasting roof.
A new level of testing evolved as a result
of the hurricanes that struck Florida in the
1990s, particularly Hurricane Andrew in
South Florida. In the aftermath of that
storm, building materials were found to be
substandard. Miami-Dade County established
an entirely new series of standards
for all building materials to be used in the
county, which differs somewhat from the
ASTM standards.
The Miami-Dade testing incorporates
three distinct tests, one of which uses the
three ASTM standards. Miami-Dade re –
quires a physical properties test, which
includes the modulus-of-rupture, water
absorption, and depth-of-softening tests.
Unlike the updated ASTM C 406, Miami-
Dade uses the previous 9,000-psi standard
for its modulus-of-rupture test. Adjacent
are the results of a test on Vermont slate in
October 2007 with the results of the physical
properties test and statement of compliance.
The second test, TAS 102-95, is a static
uplift resistance test for mechanically
attached systems. This test measures the
breaking point of the material in ft-lbs.
Tables 5A and 5B are the results of testing
on the same material as in Table 4.
The third Miami-Dade test is a wind-driven
rain resistance test in which a specified
amount of simulated rainfall is applied to a
roof deck with a specific pitch at varied
wind velocities to test the roofing product.
Water is applied up to 8.8 in/hr at wind
speeds up to 110 mph to test the material
and deck for water infiltration. Table 6
shows results of the 2007 test.
Using all this information, anyone
involved in a slate roofing project can
understand why S-1 slate is a necessity.
Manufacturers should be able to provide
recent testing results of their materials.
This is becoming more important as imported
slate continues to be shipped to the U.S.
Imported material should have to conform
to these same ASTM standards and certification
should be required that the material
tested is from the same quarry as the material
shipped. If current testing results and
quarry certification cannot be obtained, one
should question the origin and quality of
the material.
The National Slate Association is working
on recommending and certifying testing
labs. At this time, each manufacturer or
quarry uses its own criteria on how often to
Table 6 – Hurricane test results on Vermont slate.
TAS 100-95,
WIND-DRIVEN RAIN RESISTANCE TEST RESULTS
Slope: 2/12 Air Temperature: 86˚F Deck Conditioning: None required
TAS 102-95, STATIC UPLIFT RESISTANCE TEST RESULTS
Number of test tiles measured 12
Average angle: α (degrees) 2.0
Average weight: W (lbF) 6.2
Average ultimate load: F′ (lbF) 93
Percent deviation from the mean 4.0
Minimum characteristic resistance load: F′ (lbF) 43.3
Attachment resistance exp. as a Moment: (Mf) 54.5
Aerodynamic multiplier: λ 0.438
Tables 5A and 5B – Test results of TAS 102-95, static uplift test, for slate mechanically
fastened with two 1-7/8-in ring shank copper nails to 30/90 roofing underlayment.
RESTORING MOMENTS DUE TO GRAVITY MG, FT-LB
Slope: (in) ≤ 2:12 ≤ 3:12 ≤ 4:12 ≤ 5:12 ≤ 6:12 ≥ 7:12
Direct to deck 5.16 5.13 5.05 4.94 4.77 4.55
Air Velocity Condition Simulated Rainfall Condition Duration
35 mph 8.8 in/hr 15 min
No slate movement No water infiltration under deck
0 mph Off 10 min
No slate movement No water infiltration under deck
70 mph 8.8 in/hr 15 min
No slate movement No water infiltration under deck
0 mph Off 10 min
No slate movement No water infiltration under deck
90 mph 8.8 in/hr 15 min
No slate movement No water infiltration under deck
0 mph Off 10 min
No slate movement No water infiltration under deck
110 mph 8.8 in/hr 5 min
No slate movement No water infiltration under deck
0 mph Off 10 min
No slate movement No water infiltration under deck
40 • I N T E R FA C E OC T O B E R 2008
U.S.’S FUTURE HOUSE PROJECT PROCEEDS
China’s economy has experienced a remarkable rate of economic growth, ranging
from 9 to 10% annually, for two decades. One consequence is an increasing concern over
the nation’s environmental pollution.
One area that has not modernized at the same rate as other economic sectors is
housing. As a result, in 2003, China’s Ministry of Construction authorized a project
aimed at integrating the use of new and renewable energy sources, energy conservation
technologies, environmental compatibility, pollution reduction, and the use of modern
digital technologies to create a housing design that will address both the need for modern
housing and the need to reduce environmental contamination.
The “Future House Community” project includes ten houses from nine countries:
U.S., Germany, Italy, Japan, South Korea, Spain, and Sweden displayed at the site of the
2008 Olympics. Each country has de signed and built a house that reflects its own technological
capabilities and aesthetic sensibilities. The U.S. team was lead by a group from
Florida International University. FIU was asked to participate after it won first place in
Energy Balance at the 2005 National Solar Decathlon in Washington, DC.
The “Future House” FIU team chose a stone-coated, recycled aluminum and zinc roof
by DECRA Tile to eliminate polluting particle runoff that occurs with asphalt shingles. It
was installed on a batten system. A recent test by Oak Ridge National Laboratory compared
products installed direct to the deck (such as asphalt shingles), and those installed
on a batten system. The test concluded the over-the-deck venting
system created by the battens was key in keeping heated air out of
the conditioned space. In fact, it was just as important as increasing
solar reflectivity of the roof color.
For more, see www.youtube.com/watch?v=Dsk-vzsy8oQ.
www.futurehouseusa.org and other sources
test its slate, as there is no uniform standard.
While it would be helpful to have the
most recent testing results, it is time consuming
and expensive to test more than
once every year or two. The National Slate
Association should be addressing this issue
in the near future to create a standard for
all manufacturers.
References
1 Hill, Jonathan, “Standards for Test –
ing Roofing Slate,” December 2003,
Na tional Slate Association, www.slate–
association.org/standards.html>
Matthew Hicks has been with Evergreen Slate Co., which his
grandfather started in 1916, for over 25 years. He currently
coordinates all material testing, including Miami-Dade
approvals, for Evergreen. He is a member of the board of
directors of the National Slate Association, serving on its
Standards Committee. He is also a board member of the Slate
Valley Museum.
Matthew Hicks
OC T O B E R 2008 I N T E R FA C E • 4 1
Soprema, with its headquarters in Strasbourg, France, was founded in 1908 by
Charles Geisen, who invented the “mammoth membrane.” Today, Pierre Etienne
Binschedler acts as Soprema group chairman and is the third generation of the founding
family. The company has more than 2,700 employees in Europe and North America
specializing in waterproofing, smoke extraction, skylights, and contracting (Europe
only). Sales for 2008 are projected at 1 billion euros. The company has nine plants producing
SBS-engineered asphaltic membranes, three liquid-coating plants, three skylight
and smoke-extraction plants, and two synthetic-membrane plants worldwide. This year
marks the 25th anniversary of Soprema’s waterproofing materials manufacture.
SOPREMA MARKS CENTURY