Tile roofs may be made of clay,
concrete, or manufactured ma –
terial: strong, versatile, durable
materials. For over a century,
these roofs have been used
successfully. They are now
available in many architectural dimensions,
adding an aesthetic appeal, be it
American Colonial, Spanish
Hacienda, or French Provincial.
However, as with any moisturemanaged
product, the proper application
of underlayments and flashing
and integration with the building’s
other weather-resistant systems
are crucial. The key to the
proper installation of the systems is
understanding them and the need
for their integration. Any product
that has a life expectancy of greater
than 50 years will require that the
adjoining and underlying systems
also meet this life expectancy.
Sometimes an expert should be
engaged to properly integrate these
systems into a project.
BUILDING CODES
Standard building codes in the
United States, including the Uni –
form Building Code (UBC), the Inter –
national Building Code (IBC), and
the International Residential Code
(IRC), as well as adoptions in specific
local jurisdictions, provide only
the minimum prescriptive requirements for
installing roofing products. Industry and
manufacturer standards supplement the
minimum standards of building codes and
help ensure quality installation of tile roof
systems. These guidelines include those
provided by the National Roofing Con trac –
tors Association, the Roof Tile Institute, and
the Western States Roofing Contractors
Association. Standards for the manufactured
product are provided in the Eval –
uation Service Reports and the specific
manufacturer’s installation instructions.
The basic idea of the guidelines and
Photo 1 – Damage due to snow and ice accumulation in the valley area. The edge of the tile and
the supporting valley flashing must provide structurally sound products in this area.
28 • I N T E R FA C E S E P T E M B E R 2011
good industry practice is that water should
be allowed to flow freely downhill and exit at
the horizontal terminations. This is fundamental
to understanding the complete
building envelope system, of which the roof
is a part. Managing moisture on the roof
involves installing waterproofing at the deck
level, not on top of the products.
THE BASICS – WEATHER PROTECTION
The first component when properly constructing
a roof is the decking. Although a
vertical slope of 2½ in 12 inches is the minimum
allowed by code, a slope of 3 inches
vertical to 12 inches horizontal should be
considered as the minimum. Where slopes
come together, a sawtooth effect is created;
with lower-slope conditions, water, snow,
and ice are prone to accumulate in these
valleys. The installer and designer should
consider these issues when determining the
slope of the roof, as well as the needs for
additional waterproofing beyond the minimum
standards of the codes and industry
standards.
The second important component is the
underlayment and how it is installed.
Minimum code lapping is not sufficient in
these valley areas. Using proper, fully
sealed underlayments, single-ply roofing or,
better yet, open-valley construction, are
considerations that are key to successful
roofing installation and design. See Photo 1.
Depending on the climatic conditions, it
is possible that two layers of underlayment
or ice and water shield products will be
needed for protection that meets the minimum
code standards. These products
should extend 2 to 4 ft inbound of the vertical
thermal insulation line of the interior of
the building to provide protection from the
slush fill located behind the ice dams.
Particular attention to detail is necessary
where valleys come within 3 ft of sidewalls.
The valley liner should be extended up the
wall, similar to curb-base flashing. This valley
liner protects the sidewall from snow
and ice accumulation and manages concentrated
water flows that will be directed
toward the wall and can splash beyond the
standard flashings and weather barriers.
See Photo 2.
The tile roofing material provides both
an aesthetic function and protection for the
weather barrier placed below it, shielding it
from direct exposure to the elements. Tile
roofs are unique in this aspect, as the primary
drainage plane is the underlayment,
not the topmost layer as with other roofing
materials, such as asphalt or wood shingles.
That is why underlayments are the
crucial components for the roof’s weatherresistant
performance. Any puncture or
tear in the underlayment should be corrected
during construction prior to installing
the tile. Damage from leaks can result in
either immediate or long-term progressive
water entry. Discovering the point of entry
is typically difficult, as water runs down the
roof deck, below the underlayment, until it
can find a breach to enter the structure.
FLASHINGS AND LAPPING
The direction and order of lapping of the
underlayment with flashing are important
to properly manage the water flow, especially
at roof penetrations, eaves, and rakes.
The underlayment should lap over the top
of penetration flashings and under the bottom,
creating a shinglelike order directing
water to the top of every layer lower in elevation.
This technique of water shedding is
important at all penetrations, whether
plumbing and roof vents or large penetrations
such as skylights and chimneys. The
flashing surrounding these large penetrations
consists of several pieces, so the same
shinglelike lapping is essential to achieve
waterproofing performance at these locations.
Coordinating the trades–the framer,
roofer, plumber, and mechanical subcontractors–
ensures that this simple premise of
correctly lapping the materials is achieved.
At penetrations with a width greater than
30 inches, a cricket flashing is recommend-
S E P T E M B E R 2011 I N T E R FA C E • 2 9
Photo 2 – Roof layout and an understanding of ice and snow accumulation are extremely important and should be fully considered by the
design and construction team prior to applying the roofing and integrating the building veneers.
ed to protect the area from snow and debris buildup (2006
IRC) and direct water away from the vertical walls. At rakes,
the underlayment should be lapped under the rake flashing
to protect the underlayment from moisture intrusion through
wind-driven rain or snow. At eaves, the underlayment should
be lapped over the eave flashing in order to provide a continuous
avenue for water to drain off of the roof. In all of these
cases, reverse-lapped underlayment and flashing interfaces
can result in damaged components and can eventually lead
to leaks. See Photos 3 – 6.
Photo 3 – The vertical batten prevents water in the channel
from draining into the gutter below. The ice and water
shield products must be properly integrated with the
thermal envelope and the weather-resistive decking
materials.
Photo 6 – The lapping of flashings and all moisturemanagement
materials should ensure that water is
directed down, out, and away from the roofing felts.
In no case should mastic or sealant be relied upon to
correct deficient construction.
Photo 5 – The integration of the flashing from the
roofing and the sidewall cladding is extremely
important. The roofing subcontractor must ensure that
the roofing felts, waterproofing, continuous flashing,
and diverter flashing are all coordinated so they lap
properly. A situation like the one in the photograph
above should be brought to the attention of the
designer of record. The window is damaged due to the
location of the gutter, and because without flashings,
water is directed into the jamb of the window.
Contractors and subcontractors should not proceed
with their work until such situations are fully resolved.
30 • I N T E R FA C E S E P T E M B E R 2011
Photo 4 – The integration of penetrations through the
roofing requires that the roofing subcontractor work with
the plumbing subcontractor to ensure that the lower
flashings are integrated in a shingle-lapped manner and
sealed, and that the upper flashings are integrated with
the tile and sealed. In this case, the penetration near
the valley is a problematic detail that should not occur.
Simply put, keep holes out of valley construction.
VALLEYS
It is important to pay
close attention to the
design and construction of
the underlayment in the
valleys. Valleys are created
at the intersection of two
sloping roof planes; this
intersection creates a natural
area of concentrated
water flow. Where water
and ice are concentrated,
additional protection of
the underlayments is re –
quired. Simply placing
more underlayment or
using sheet metal flashing
at valleys isn’t enough; the
installation must carry
both the lateral and longitudinal
concentrated flow
of water without becoming
saturated or allowing
water to pass through
gaps or penetrations.
Prop erly lapping components in a shinglelike
manner directs water from above
each layer of underlayment and flashing; as
water flows down the roof, it remains on top
of the moisture-management materials. It is
preferred to use open valleys rather than
tiling across the valley. An open valley
makes it easier to clean out debris.
Additionally, the damage from ice accumulation
in an open valley is more limited than
in a closed valley with cut tiles over battens
or flashings. Valleys should never terminate
within 6 inches of a sidewall, as the concentrated
flow will result in water impacting
the vertical veneer systems. See Photos 7
and 8.
ICE DAMS
Ice dams are not an uncommon problem
in mixed or cold climates; ice damming conditions
can result in premature damage to
the roof, walls, or interstitial space from
moisture intrusion, the weight of the dam,
or ice falling on lower surfaces or other
building components. These ice dams can
S E P T E M B E R 2011 I N T E R FA C E • 3 1
Photo 7 – This valley is
constructed with horizontal
battens that will trap
debris. The use of a closed
valley requires that tiles be
removed in order to perform
the required maintenance.
Photo 8 – Poor valley
design by the architect is
shown here. The design
directs water into the
vertical unit-demising
wall and allows buildup
of ice and snow against
the cladding.
also cause serious injury if they
fall on pedestrians. The formation
of ice dams can be minimized
by good design and construction.
See Photo 9.
Two events are necessary to
create an ice dam: a warm interior
attic or rafter and a cold
exterior surface that freezes.
When snow accumulates on a
roof with a warm attic, the snow
sitting on the warm part will
melt and become liquid; when
this water reaches the eaves,
which are cooler than the attic
space, it freezes. Over time, this
ice accumulates and can create
a potentially hazardous ice
dam. Additionally, exposing the
moisture-management materials
underneath to ice and water
for prolonged periods of time
accelerates the deterioration of
the materials. Deteriorated
moisture-management components
lead to damage of the
building. See Figure 1.
There are various options
when designing attics that will
minimize the warming effects that result in
snow melt, ice formation, and subsequent
ice dams at the colder roof areas. The
design should include a good thermal and
pressure boundary. The pressure boundary,
like the building envelope on the exterior,
controls the movement of air and water
or water vapor. There are several important
things to consider when creating this
boundary. The first is to clearly establish a
pressure boundary that coincides with the
thermal boundary, which is most commonly
insulation in the walls and ceilings.
Convective air should not move from the
interior side of the home into the unconditioned
spaces. The key to preventing this
movement is placing the insulation in direct
contact with the air barrier. Using kraftfaced
batts will not provide the vapor diffusion
or air pressure boundary necessary for
thermal continuity; instead, using expanding
insulations will likely establish the best
air and thermal line, but other options
include overventing a well-insulated attic to
minimize the temperatures within the attic.
The caution of this design, however, is
there is a potential of creating higher negative
pressures that bring in air from the
eaves or birdhouse ridge; it’s important to
ensure snow is not pulled into the attic
space due to this negative pressure.
Figure 1 – A warm attic space can heat the field of a roof during winter conditions. Snow
will then melt, flow to the colder, exterior edges of the roof, then refreeze. This creates ice
dams that can lead to the deterioration of the roofing materials, as well as pose a lifesafety
hazard from falling ice.
32 • I N T E R FA C E S E P T E M B E R 2011
Photo 9 – Snow damage of the cleats and tiles due to build-up of ice and snow behind the retention
bars. The clips do not have structural capacity to resist the loads imparted from the sliding ice and
snow.
Properly isolating mechanical chases thermally
from the attic will help minimize
increased temperatures originating from the
house. The common B-vent discharge is
sufficient enough to raise the attic temperature
to provide snowmelt.
FASTENING AND BATTENS SUPPORTING TILE ROOFS
Wood battens are used to provide a
means to attach the tile system and allow
for drainage at the roofing felt level. The
tiles can lie over the batten, or they can be
fastened through the batten. It is typical to
use fully fastened tiles in wind zones over
the 100-mph fastest gust. In fact, the code
requires this fastening, as well as fastening
the rake tiles (tiles on the outside, sloped
edges of the roof) with two nails. If design
wind speeds are in excess of the 110-mph
fastest gust, the installer must fasten the
tiles to provide resistance to uplift loads in
accordance with the structural load calculated
for the zones of the roof under
Chapter 16 of the IBC.
When battens have lugs, the slope of the
roof dictates the fastening system, up to the
100-mph fastest gust and the structural
calculations for wind designs in excess of
110 mph. The tiles with projecting anchor
lugs can be relied on without fastening to
the battens for winds below 100 mph and
slopes under a 5:12 pitch. Interlocking tiles
with projected anchor lugs always require
fastening to battens. The international
codes simply state that for areas with snow,
at least two fasteners per tile are required,
or one fastener if used with battens. See
Photos 10 – 12.
The codes are silent on batten type and
installation. The battens are defined in
guidelines such as the Roof Tile Institute’s
Design Criteria. One needs to consider the
wood type in combination with the use of
horizontal or vertical systems. Horizontal
battens run perpendicular to the slope of
the roof and will trap moisture. A 1-in slot
should be placed every 4 ft to provide for
drainage, and clearance of at least 6 in from
the valley to allow concentrated flow is preferred.
When deciding to use horizontal batten-
only support, the longevity of the system
beneath the tile should be considered
because without provisions for drainage,
the lifespan of the roof may be reduced.
Knowing that the water will be absorbed
and retained against the roofing felts, allowing
for deterioration, consider using red-
You want a tested and trusted roofing material – not one that cracks
under pressure. Why specify roofing materials that age prematurely,
unable to withstand the elements? Roofing membranes should perform
for decades – are you settling for less?
Use your QR code reader to get the facts
or visit www.vinylroofs.org/compare
Is your roofing
material cracking
under the elements?
Infrared Roof
Moisture Surveys
www.irtest.com | 1.888.925.4404
The Professionals Choice
Nationwide • Since 1977
Certified • RCI member
Please note that we do not offer
roof design, construction management,
or repair services.
Infrared Consulting
Services, Inc.
S E P T E M B E R 2011 I N T E R FA C E • 3 3
wood, cedar, or treated wood, as they
provide a longer-life product.
When using vertical battens, better
known as counterbatten systems, a minimum
space of three-quarters of an inch
for drainage is created, and the vertical
battens provide a flow path for both
water and air. This system will outperform
horizontal batten systems, and the
life of the underlayment matches the life
of the tile. The structural loads must be
included for counterbatten systems,
including the batten sizing, as they act
as either simple support beams or multispan
beams, depending on location.
Snow loads of 30 pounds per sq ft (psf)
require the horizontal batten spanning
to the vertical battens to be Douglas fir
or better when spaced over vertical bat-
Photo 10 – The installer must determine the
proper fastening and location. This as-built
condition shows the nail size chosen and that
there are missing nails in the tile roofing.
Photo 11 – The vertical battens must be
nailed in order to transfer the wind load;
after that, the horizontals must be nailed
to the verticals, then the tiles to the
horizontals. If not, there must be
sufficient weight to resist wind uplift.
Roof edges will have sufficiently
increased uplift loads and will require
additional fastening or clipping.
Photo 12 – Horizontal battens require that
water drain to the slots. In order for that to
happen, water must back up and work its
way to the drainage slot. In the photo below,
the slot appears to have been cut after the
installation of the batts; this creates an
opening in the roofing felts for the water to
drain through. Vertical battens with the
horizontal battens applied over the top are
preferred over this type of installation
because they create a direct and
uninterrupted path to the edge of the roof.
34 • I N T E R FA C E S E P T E M B E R 2011
tens at 16 inches on center. For cedar, 1 x
4s would be required to handle the snow
loads.
Roofs are an essential component of the
building envelope system for any structure.
Tile roofs are an effective and aesthetically
pleasing system if installed correctly.
Underlayment, directional lapping, battens,
and fasteners are frequently overlooked
facets of tile roof construction that can make
or break any roof assembly. If one is diligent
during installation and proper maintenance
is performed throughout the life of the roof,
tile roofs can protect the interior environment
of a building for years.
Edward L. Fronapfel, PE, holds bachelor’s and master’s
degrees in civil engineering with an emphasis in structural
engineering. He is a certified Level 2 infrared thermographer,
a certified third-party EIFS inspector, a certified forensic
claims consultant (CFCC), and a board-certified building
inspection engineer (CBIE). Fronapfel’s background includes
geohydrology, hydrology, hydraulics, civil engineering, structural
engineering, and extensive work in construction forensics
for building envelope sciences, including asphalt work to
the roof. Ed’s work has included deposition testimony, expert witness testimony, mediations,
and arbitrations. He is a registered engineer in 23 states. His dedication to the
community is demonstrated by his active membership in 25 professional organizations.
He has published articles in various industry publications.
Edward L. Fronapfel, PE
To view the International Code Council’s (ICC) proposed International Green Construction Code (IgCC), visit
http://www.iccsafe.org/cs/IGCC/Pages/IGCCDownloadV2.aspx. In development for the past two years, the IgCC is
scheduled to be published in March 2012. Local jurisdictions will begin to develop the code in earnest after that
point. The code development committees heard more than 1,250 proposed changes (including some submitted by
RCI and NRCA) to the second public version in May. The final action hearing is scheduled for November, after
which the final document will be prepared for publication. The new codes will undoubtedly have an impact on
building envelope consultants.
CHECK OUT PROPOSED IGCC