Skip to main content Skip to footer

Understanding Acoustics for Dynamic Building Enclosures With Wind-Driven Kinetic Façade Systems

May 15, 2020

24 • IIBEC Interface A August 2020
Figure 1 – Wind-driven kinetic façade systems create an ever-changing exterior. Translucent flapper panels, such as on Pittsburgh Children’s Museum’s “Articulated Cloud,” allow natural light to enter the interior, while reducing unwanted solar heat gain and glare. The museum’s façade system was collaboratively designed and built by artist Ned Kahn, architects Koning Eizenberg, and façade manufacturer EXTECH. All photos courtesy of EXTECH.
Wind-driven kinetic
façade systems often
are constructed of
hundreds or thousands
of moving parts
to provide the intentional
dynamic effect for a building
enclosure or structure. Responding to
air currents, the flapper panel design
creates the look of rolling waves
across the wall. Designed to
attract attention, these systems
typically are installed on buildings
in dense, urban areas.
Along with creating visual
interest with their movement,
all kinetic installations
can produce
some level of ambient
sound under higher
wind conditions
(Figure 1).
Manufacturers can engineer and fabricate
kinetic façade systems with spacers
between the flappers to reduce the collateral
noise. While aluminum is the most popular
material for flappers, other options include
perforated materials, stainless steel, polycarbonate,
polytetrafluoroethylene (PTFE),
acrylic, and even polyvinylidene fluoride
(PVDF) films (Figure 2). The construction
material, suspension system, and flapper
geometry can be adjusted to ensure that
the level, tone, and timbre of the resulting
sound is acceptable.
The volume and quality of sound generated
by a kinetic façade installation should
be considered as early as possible in the
design and specification process. Sound
levels can be verified with full-scale mockups
to ensure that the wind-driven façade
systems are within acceptable levels.
MEASURING SOUND
• A decibel (dB) is a unit of measurement
for sound.
• A-weighted decibels (dBA) are an
expression of the sound pressure
level scale, or relative loudness of
sounds in air, as perceived by conscious,
healthy human ears.
Be aware that dB and dBA measurements
are logarithmic rather than linear.
This has implications for interpreting perceived
loudness and comparing levels and
perceived loudness differences. For every
10 dBA change in the sound pressure level,
the perceived loudness changes by a factor
of two. For instance, a 10-dBA increase in
level will sound twice as loud to the average
listener, and a 10-dBA decrease will sound
half as loud. A 20-dBA change thus corresponds
to an increase/decrease in loudness
by a factor of four—four times louder or
one-quarter as loud. A 3-dBA change is the
smallest change perceptible to a listener
with normal/average hearing.
NOISE ORDINANCES
Many municipalities have ordinances
that prohibit unnecessary, excessive, and
annoying noises. These noises include those
emanating from within buildings, and also
can include sounds generated by constructing
or operating the structures themselves.
For example, the Minneapolis city ordinance
states: “Excessive noise degrades the
environment to a degree that [it]:
• Is harmful to the health, welfare,
and safety of its inhabitants
• Interferes with the comfortable
enjoyment of life and property
• Interferes with the well-being, tranquility,
and privacy of the home
• Causes and/or aggravates health
problems”
In Minneapolis, “Regulating noise
should and does take into account the
time, place, and manner of such noise.” In
practice, this becomes complicated, because
different times and noise levels are permitted,
depending on the source of the sound
A u g u s t 2 0 2 0 I I B E C I n t e r f a ce • 2 5
Figure 2 – While aluminum is the most popular material
for flappers in wind-driven kinetic façade systems, other
options include perforated materials, stainless steel,
polycarbonate, PTFE, acrylic, and even PVDF films.
and the noise-generating activity’s purpose.
Commonly, city ordinances’ sound levels
and frequencies are different for daytime
and nighttime hours. This generally
includes guidance on acceptable distances
from residences and approved daytime
hours for operating lawnmowers, landscaping
equipment, power tools, loud motorized
vehicles, or construction equipment;
performing garbage collection; or allowing
amplified music.
As another example, the noise ordinance
for Los Angeles categorizes the city
into four major zones and, depending on the
typical activity level in each zone, assumes
an ambient 7 a.m. to 10 p.m. daytime
noise level of 50-65 dBA for sounds within
a residence or within 500 feet of a residence.
The acceptable nighttime ambient
level is reduced by approximately 5-10 dBA
between 10 p.m. and 7 a.m.1
Furthermore, the Los Angeles ordinance
states that noise in any place of public
entertainment at a sound level greater than
95 dBA is unlawful unless there is signage
placed outside and near each public
entrance, stating: “Warning: Sound levels
within may cause hearing impairment.”
Local noise ordinances also may provide
rules and exceptions for hospitals, schools,
places of worship, and commercial business
districts. In addition, state and federal
guidelines may take priority for emergency
work or for regulated industries, vehicles,
and properties such as train whistles and
airports.
Violations may be subject to fines or
other punitive actions. In Los Angeles,
and similarly, in other municipalities, law
enforcement may determine whether a violation
has occurred based on factors including,
but not limited to:
• The level of noise
• Whether the nature of the noise is
usual or unusual
• Whether the origin of the noise is
natural or unnatural
• The level and intensity of the background
noise, if any
• The proximity of the noise to residential
sleeping facilities
• The nature and zoning of the area
within which the noise emanates
• The density of the inhabitation of the
area within which the noise emanates
• The time of day and night the noise
occurs
• The duration of the noise
• Whether the noise is recurrent,
intermittent, or constant
• Whether the noise is produced by a
commercial or noncommercial activity
ACCEPTABLE EXPOSURE
To provide a basis for state and local
governments’ judgments in setting standards,
the U.S. Environmental Protection
Agency (EPA) identifies:
2 6 • I I B E C I n t e r f a ce A u g u s t 2 0 2 0
Figure 3 – Treasure Island Center’s wind-driven kinetic façade system installed on the
building’s top exterior corner visually attracts visitors’ attention in a busy part of downtown
St. Paul, Minnesota.
Figure 4 – Logan International Airport’s Walkway and West Garage features a wind-driven
kinetic façade system with 48,000 aluminum flapper panels to screen the parking structure.
Designed by architectural firm Arrowstreet Inc. in collaboration with façade manufacturer
EXTECH, the garage’s dynamic wall enhances the view for the traveling public.
…a 24-hour exposure level of 70 dB as the level of environmental noise, which will prevent any measurable hearing loss over a lifetime. Likewise, levels of 55 dB outdoors and 45 dB indoors are identified as preventing activity interference and annoyance. These levels of noise are considered those which will permit spoken conversation and other activities, such as sleeping, working, and recreation, which are part of the daily human condition.2
The EPA’s noise levels represent averages of acoustic energy over periods of time, such as 8 hours or 24 hours, and over long periods of time, such as years. The level of 70 dB is identified for all areas to prevent hearing loss.
Even with the EPA-stated 70-dB safe level, other U.S. regulations and guidelines vary on acceptable noise levels and duration.
•The Centers for Disease Control andPrevention agrees with the EPA andexpands to say, “Noise above 70 dBover a prolonged period of time maystart to damage your hearing. Loudnoise above 120 dB can cause immediate harm to your ears.”3
•The Occupational Safety and HealthAdministration’s (OSHA) permissible exposure limit is 90 dBA forall workers for an eight-hour day.The OSHA standard uses a 5-dBAexchange rate. This means that whenthe noise level is increased by 5 dBA,the amount of time a person can beexposed to a certain noise level toreceive the same dose is cut in half.4
•The National Institute for OccupationalSafety and Health (NIOSH) has recommended that all worker exposures tonoise should be controlled below alevel equivalent to 85 dBA for eighthours to minimize occupationalnoise-induced hearing loss. NIOSHalso recommends a 3-dBA exchangerate, such that every increase by 3dBA doubles the amount of the noiseand halves the recommended amountof exposure time.5
NOISE-INDUCED HEARING LOSS
Regardless of whether the source is inside, outside, or as a result of a building structure, unwanted sounds quickly can become perceived as noise. Sustained, loud, or high frequency noises are proven to have negative consequences on human health.
The U.S. Department of Health and Human Services’ National Institutes of Health (NIH) and the National Institute on Deafness and Other Communication Disorders (NIDCD) cautions, “Sounds can be harmful when they are too loud, even for a brief time, or when they are both loud and long-lasting. These sounds can damage sensitive structures in the inner ear and cause noise-induced hearing loss (NIHL).”6
Humans perceive noise by converting sound waves in the air into electrical signals that register in the brain. Sound waves enter through the outer ear and travel through the ear canal, causing the eardrum to vibrate. Three tiny bones in the middle ear convert the sound vibrations from air to fluid vibrations in the cochlea of the inner ear.
NIDCD explains that most NIHL is caused by the damage and eventual death of stereocilia—microscopic hair-like projections in the inner ear:
A
ugust 2020 IIBEC InterfaceCE • 27The Original & Best Performing Liquid FlashingRwww.apoc.com • (800)562-5669Ideal for Roofing, Waterproofing & Building Envelope ApplicationsFast Install with up to 50% Labor SavingsSolid Monolithic & Waterproof ConfigurationUse on Vertical or Horizontal ApplicationsAvailable in Multiple Sizes & ContainersR
Once the vibrations cause the fluid inside the cochlea to ripple, a traveling wave forms along the basilar membrane. Hair cells – sensory cells sitting on top of the basilar membrane – ride the wave. …The stereocilia that perch on top of the hair cells bump against an overlying structure and bend. Bending causes pore-like channels, which are at the tips of the stereocilia, to open up. When that happens, chemicals rush into the cell, creating an electrical signal. The auditory nerve carries this electrical signal to the brain, which translates it into a sound that we recognize and understand.7
“The louder the sound, the shorter the amount of time it takes for NIHL to happen,” concludes NIDCD.
The Hearing Health Foundation estimates nearly 50 million Americans, including one in five teenagers, suffer from NIHL. It adds that “regular exposure of more than 60 seconds at or above 110 dB risks permanent hearing loss. Prolonged exposure to any noise at or above 85 dB can cause gradual hearing loss. No more than 15 minutes of unprotected exposure at or above 100 dB is recommended.”8
ACOUSTICAL STUDY OF WIND-DRIVEN FAÇADE SYSTEMS
As of January 2020, no available research could be located that effectively recorded the sound levels generated by wind-driven kinetic façade systems.
EXTECH/Exterior Technologies, Inc. commissioned an acoustical study to model and predict the sound that would be emitted by a pin-mounted, wind-driven façade system installation in the areas surrounding the building structure. The study would assess the sound relative to objective levels and limits as compared to applicable noise ordinance and regulations, and to subjective human perception of what a nearby listener would hear.
A physical test unit was constructed to evaluate a kinetic façade system’s structural dynamic behavior, and to measure the sound generated by wind-induced motion of its flappers and its support structures (Figure 5). This test unit consisted of:
28 • IIBEC InterfaceCE A August 2020
Figure 5 – A physical test unit was constructed with 32 flapper panels and a 2-point pin-mount suspension system to evaluate a wind-driven kinetic façade system’s structural dynamic behavior, and to measure the sound generated by wind-induced motion.
Typical
sound Sound source
levels (dBA)
170
Shotgun firing
162
Firecracker (3 feet away)
150
Jet taking off
140
Threshold of pain for an average listener
130
Jackhammer and operating heavy equipment
120
Ambulance siren; thunderclap
110
Shouting directly in the ear; rock concerts; sporting events
105-110
Music
through headphones at maximum volume
95-110
Motorcycles
and dirt bikes
90-115
Approaching
subway train; construction site
85
Heavy city traffic; busy restaurant; hand saw
80-90
Food
processor; blender
74-104
Movie
theater
70-95
Coffee
grinder; garbage disposal
70
Freeway traffic
60-70
Normal
conversation (3 feet away)
60-95
Hair
dryer; vacuum; power lawnmower
50-75
Refrigerator;
dishwasher; washing machine; air conditioner
50
Rainfall; large office
40
Library; quiet residential area
30
North rim of Grand Canyon
20
Ticking watch; whisper (5 feet away)
10
Normal breathing
3
Smallest perceptible change in sound to an average listener
Table 1 – Typical sound levels. From Center for Hearing and Communication, Centers for Disease Control, Environmental Protection Agency, Hearing Health Foundation, NIDCD, NIOSH, and OSHA.
• 22.2-sq.-ft. overall area
• 32 8-sq.-in. flapper panels manufactured
with 0.040-in.-thick 3003 alloy
aluminum with mounting holes, and
finished in a polyvinylidene fluoride
(PVDF, Kynar®) architectural coating
on the fronts and a wash coat on the
backs
• 2-in. spacing on all sides
• 2-point, pin-mount suspension system,
including 300 stainless steel
supports
• Sound-dampening bushing
• Extruded aluminum framing
• Flappers set for 80 degrees total
movement
A pin-mount suspension on a wind-driven
façade system allows the flapper elements
to seemingly float
in front of the
support rungs
and side rails as
a veil (Figure 6).
This configuration
minimizes
the appearance
of the supporting
structure and
makes it convenient
to create
innovative aesthetic
designs by
mixing flapper
shapes to create geometric patterns.
This type of suspension also makes
installation possible at various mounting
points, facilitating changes in kinetic activity.
Pin-mount suspension systems allow
the flappers to be removed and replaced
without any specialized tools if repair or
maintenance is needed (Figure 7).
A u g u s t 2 0 2 0 I I B E C I n t e r f a ce • 2 9
Figure 6 – A pin-mount suspension on a wind-driven kinetic
façade system allows the flapper elements to seemingly float in
front of the support rungs and side rails as a veil.
Figure 7 – Pin-mount suspension systems allow the flappers to be
removed and replaced without any specialized tools if repair or
maintenance is needed on wind-driven kinetic façade systems.
The test unit was installed in a large open field in a high-wind area of rural western Pennsylvania (Figure 8). This location was selected due to its minimal extraneous ambient noise sources, reducing the potential for background noise to contaminate the study. The test unit was exposed to varying wind conditions, and the wind-induced sound was measured and correlated with the wind parameters.
The data collected from the test unit were then applied to a larger, wind-driven façade model on a full-scale building elevation (Figure 9). The building elevation dimensions were:
•North facing
•55-ft. high, four floors tall
•560.5-ft. long
•21,632 sq. ft. of moving flapper panels installed 8 ft. above grade
The model was used to predict the aggregate sound that would be emitted at increasing distances from the building’s wind-driven kinetic façade systems. Sound levels were calculated at ground level from the building’s center (280.5 ft.) (Table 2) and at approximately 140 ft. from the building’s corner (Table 3).
For the quietest predicted sound level of 35 dBA, a person would need to stand 100 feet from the building with a 5-mph wind blowing. This would be the equivalent of hearing a soft voice at a distance of 5 feet.
For the loudest predicted sound level of 62 dBA, a person would need to stand immediately in front of the building (0.0 ft.) with a 25-mph wind blowing the kinetic façade system. This “noise” would be the equivalent of hearing a conversation at a distance of 3 ft. (Figure 10).9
Research shows that installed in an
30 • IIBEC InterfaceCE A August 2020
Figure 9 – The data collected from the wind-driven kinetic façade test unit were then applied to a larger, wind-driven façade model on a full-scale building elevation.
Figure 8 – Installed in a large open field in a high-wind area of rural western Pennsylvania, the wind-driven kinetic façade test unit was exposed to varying wind conditions, and the wind-induced sound was measured and correlated with the wind parameters.
urban setting, a city’s ambient noise further masks the sounds produced by a building façade. Current examples of wind-driven façade installations can be seen on airports, downtown offices, sports stadiums and event centers, high-end retail stores, museums, and parking garages. In these applications, noise from vehicle traffic, aircraft, performances, and energetic visitors help negate the sound produced from the kinetic system itself.
In addition to the location-specific noises of a kinetic wall installation, the wind inducing the flapper panels to create the system’s dynamic visual effect also will generate ambient sound. In many cases, the wind itself will be loud enough to mask the sound level of the façade system.
This acoustic study also verifies that the perceived sound levels of this type of wind-driven kinetic façade are highly unlikely to be of concern to applicable noise ordinances and regulations.
In conclusion, remember to consider the volume and quality of sound generated by a kinetic façade installation as early as possible in the project’s design and material
A
ugust 2020 IIBEC InterfaceCE • 31
Overall sound level (dBA)
measured from the center (280.5 ft) of the building elevationDistance from façade system (feet)Wind speed (mph) 0 25 50 75 100
5
40 39 38 36 35
10
43 42 41 39 38
15
46 45 44 43 41
20
50 48 47 46 44
25
57 56 54 53 52
Overall sound level (dBA)
measured from 140 feet from the building’s cornerDistance from façade system (feet)Wind speed (mph) 0 25 50 75 100
5
46 42 40 38 36
10
49 45 43 41 39
15
52 48 46 44 42
20
55 51 49 47 45
25
62 59 56 54 53
Table 2 – Sound levels calculated from 280.5 ft.
Table 3 – Sound levels calculated from 140 ft.
2021 IIBEC InternationalConvention & Trade ShowPhoenix, AZ | March 4-9, 2021
selection process. If necessary, verify sound levels and tonal quality on an individual project with a full-scale mock-up.
Given the complexity of kinetic façade systems, seek an experienced designer and manufacturer to participate early in the project’s design. Look for one offering preliminary cost estimating, mock-ups, and a variety of fabrication and installation options to meet each project’s functional and aesthetic requirements.
REFERENCES
1.The Los Angeles ordinance states:“Sound Level Meter” is an instrument including a microphone, anamplifier, an output meter, and “A”frequency weighting network for themeasurement of sound levels whichsatisfies the pertinent requirementsfor Type S2A meters in AmericanStandard Specifications for soundlevel meters in S1.4-1971 or the mostrecent revision thereof. (Amended byOrd. No. 156,363, Eff. 3/29/82.)
2.Environmental Protection AgencyOffice of Noise Abatement andControl. Information on Levels ofEnvironmental Noise Requisite toProtect Public Health and Welfare With an Adequate Margin of Safety. 550/9-74-004. March 1974. https://nepis.epa.gov/Exe/ZyPDF.cgi/2000L3LN.PDF?Dockey=2000L3LN.PDF
3.Centers for Disease Control andPrevention. “What Noises CauseHearing Loss?” Oct. 7, 2019.https://www.cdc.gov/nceh/hearing_loss/what_noises_cause_hearing_loss.html
4.United States Department ofLabor Occupational Safety andHealth Administration. 1910.95 –Occupational Noise Exposure. Part1910 Subpart G. https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.95
5.National Institute for OccupationalSafety and Health. “Noise andHearing Loss Prevention Guidanceand Regulations” “OccupationalNoise Exposure.” 1998. https://www.cdc.gov/niosh/topics/noise/reducenoiseexposure/regsguidance.html and https://www.cdc.gov/niosh/docs/98-126/pdfs/98-126.pdf?id=10.26616/NIOSHPUB98126
6.National Institute on Deafness andOther Communication Disorders.“Noise-Induced Hearing Loss.”Updated March 2014. https://www.nidcd.nih.gov/health/noise-induced-hearing-loss
7.Ibid.
8.Hearing Health Foundation.“Hearing Loss & Tinnitus Statistics.”Accessed June 30, 2020. https://hearinghealthfoundation.org/hearing-loss-tinnitus-statistics. Seealso: World Health Organization.“Deafness and Hearing Loss.” March1, 2020. https://www.who.int/news-room/fact-sheets/detail/deafness-and-hearing-loss
9.The study did not evaluate noise athigher wind speeds. Higher soundlevels may be expected, dependenton material selection and detailing;however, as wind speed increases,so does the surrounding ambientnoise, which can mask that produced by the kinetic façade.
32 • IIBEC InterfaceCE A August 2020
Kevin Smith is a registered architect and leads EXTECH’s team of architects and engineers as director of product application and development. He brings more than three decades of experience in designing commercial, civil, industrial, and transportation projects, as well as daylighting and static and kinetic façades. He earned a bachelor of architecture degree from Carnegie Mellon University. Smith may be reached at ksmith@extechinc.com.
Kevin Smith
Jim Leslie is the general manager of EXTECH/Exterior Technologies, Inc., in Pittsburgh, PA. He and his team redefine the intersection between the natural and built environments with wall, window, skylight, canopy,and custom systems, such as dynamic façade designs. Leslie has a bachelor of science in mathematics from Penn State University and is a member of the American Production and Inventory Control Society (APICS). He may be reached at jleslie@extechinc.com.
Jim Leslie
Figure 10 – The overall sound pressure level produced by the wind-driven kinetic façade test unit is plotted as a function of distance for 10- and 25-mph wind speeds. Chart by EXTECH.