Skip to main content Skip to footer

Publication Types & Categories: Technical Article

Tearing Off the Foam Plastic Insulation May Be Unnecessary. The History of SPRI’s Re-cover Subcommittee Activities

May 15, 2004

Throughout the 1980s, as the use of single-ply membranes grew, the practice of recovering existing roof systems also grew, primarily because single-ply systems were considered less vulnerable to moisture under the new membrane than was traditional BUR. Re-cover roof projects grew from approximately 11 percent of all low-slope roofing activity in 1983 to 22 percent […]

Read More

Elastomeric Acrylic Roof Coatings for EPDM Roofing

May 15, 2004

Introduction EPDM presently holds about 30 to 35% of the 3.6 billion-ft2 lowslope roofing market and is growing rapidly at the expense of other conventional roofing systems. Black EPDM membranes are the predominant choice for new low-slope roof construction today. The Environmental Protection Agency (EPA) has become a major influence in the roofing market. The […]

Read More

Drain Land Defense Keeping Roof Drains Free and Clear

May 15, 2004

July 2004 Interface • 39 The old saying, “an ounce of prevention is worth a pound of cure” can hardly be argued when it comes to good roofing practices. In this case, the problem to prevent is a clogged roof drain due to build-up of debris, leaves, and/or snow and ice around the strainer. A […]

Read More

Value Engineering of Traditional Clay Tile Dome Roofs-Lessons Learned

May 15, 2004

4 • Interface January 2004 ABSTRACT The design and construction of traditional dome roofs present several challenges. These challenges are intensified when the design criteria call for the use of clay tiles. This article discusses the design and construction of the roofing systems for the new buildings at St. John Chrysostomos Monastery in Kenosha, Wisconsin. […]

Read More

Field Performance of Spray Polyurethane Foam Flashings

May 15, 2004

6 • Interface April 2004 In September of 2003, The National Roofing Foundation completed its second field study of Spray Polyurethane Foam (SPF) roofing systems. The study, which began in 2001, examined 188 SPF roofs of various sizes and shapes. The roofs ranged in age from new to 31 years, with an average age of […]

Read More

Moisture Management of Building Envelopes: A Moisture Index Approach to Characterizing Climates for Moisture Management of Building Envelopes

May 15, 2004

INTRODUCTION Recent history has documented the premature failures of building envelopes in various regions of North America – notably on the West Coast and the East Coast [1], [2]. The problem appears, to some extent, to be influenced by climate. The MEWS (Moisture Management of Exterior Wall Systems) Consortium project, undertaken by the Internatonal Research […]

Read More